Lumber Liquidators logo

Moisture Testing Requirements



     

Moisture Testing Requirements

Approximately 85% of all installation failures result from moisture problems. Therefore, the purpose of this document is to outline typical moisture testing, planning and procedures designed to help your installation be a successful one. NOTE: adhere to adhesive labeling instructions for moisture testing and or limitations when bonding products to concrete.    

The installation of Lumber Liquidators, Inc.("LLI") wood flooring should not commence until conditions are determined to be "dry" according to industry moisture testing standards. Testing is to include, (a) the new wood or bamboo flooring and (b) the wood subfloor or cement slab.

It is the responsibility of the professional flooring contractor or the Do-It-Yourselfer (DIY) to inspect and test jobsite moisture conditions prior to the commencement of any flooring system to ensure compliance with established hardwood industry standards. It is understood that moisture testing only establishes the existence of moisture at the time of testing and does not forecast future moisture issues.  Installers would not be held responsible for moisture problems arising after the installation providing prior testing was conducted and normal moisture remediation was completed before installation. The point of moisture testing is to establish when the new flooring and substrate is actually ready for installation or the need to reschedule the work until conditions are acceptable, in other words: ensure by testing that dry flooring is applied to dry substrates.   

Testing concrete
Common testing methods for moisture
THE CALCIUM CHLORIDE TEST
THE POLYFILM TEST
THE PHENOLPHTHALEIN TEST
Testing new wood flooring and subfloors
Moisture Meters: probe and pinless

Testing concrete

 (LLI) does not recommend installation of any flooring system over a newly-installed concrete slab within 60 days of pour. Concrete slab drying time is affected by the type of construction, concrete formulation, location of the building and climatic/environmental conditions. Vapor barriers or under-slab membranes, while recommended, can increase slab-drying times, therefore accurate testing should not commence until after some 90 days of cure time. When conducting slab moisture testing, conduct tests in several areas regardless of the age of the slab. If the testing indicates a wet slab, document the results and delay installation of the flooring until corrected.

The use of an electronic concrete moisture meter to determine slab moisture emission is not reliable nor recommended. This is because electronic meters measure moisture content in the slab, usually in terms of an overall percentage and register moisture content only at 1% of the surface, while other meters register an average only in a vertical downward direction where placed. Electronic meters may indicate a presents of moisture but not the on-going emission rate that is occurring at the time.

The Following are several industry-recognized concrete slab moisture tests that provide quantitative measurements of moisture emission. All tests should be conducted at several different locations in a room, typically along exterior walls and walls with plumbing enclosures.

Common testing methods for moisture

THE CALCIUM CHLORIDE TEST : The calcium chloride test is one of the oldest and most legally recognized concrete moisture tests and is preferred by most adhesive companies. This test has been used most often by flooring retailers and contractors prior to bonding flooring to concrete and is available at most Lumber Liquidators locations for about $35 per test kit. Depending on the kit purchased, results can be acquired within a few days, or sent to a facility for documentation and reading. The calcium chloride test works by measuring changes in the dry weight of anhydrous calcium chloride crystals.

The typical procedure: a small plastic dish of anhydrous calcium crystals is weighed to determine moisture content. 1 st , after grinding a 20" x 20" square cement surface  (fig 1) the entire dish is weighed on a gram scale prior to placement and the weight, date and time the test was started must be recorded. The lid is then opened, and the dish of crystals is carefully set down on the concrete for 60 to 72 hours. The dish is enclosed within a 7-by-10-inch cover, which is then sealed with plastic tape to the concrete (fig 2) . During this time, the only source of moisture being absorbed by the anhydrous crystals is what can evaporate out of the covered concrete surface area. A note of caution: Make sure indoor climate is at normal living conditions prior to conducting the test.

At the end of the test, the dome is removed and the lid is placed back on the dish and sealed. Again the dish is weighed on the gram scale and the date and time are marked. The change in weight is multiplied by a constant and divided by hours to provide an estimated rate of evaporation, in pounds.

(fig. 1)

(fig. 2)

For example, water weighs 8.3 pounds per gallon. Pounds, is the equivalent weight of water that evaporates out of a 1,000-square foot surface area during 24 hours. If the test reports 8.3 pounds emission, then one-gallon of water is leaving a 1,000 square foot surface area in 24 hours. A conservative but generally recommended allowable amount of moisture emission as expressed by the calcium chloride test is  3.0 pounds per 1,000 square feet per 24 hours at the time of the installation of the flooring.  

THE POLYFILM TEST : Several pieces of plastic film, 18"- 24" squares of are placed at key points on the cement, seal all four sides with silver duct tape. After 24 hours, the plastic film is removed and inspected for signs of condensation. If beads of water are found on the subfloor or the concrete appears darker this is a heads-up that further testing is necessary. If there is no indication of moisture under the plastic film, one can assume the installation may proceed. The reading is valid at 24 hours, but it's even better if the test can stay in place until 72 hours have passed. The plastic film test can also be "accelerated" by using a heat source such as a 40 to 60 watt light bulb safely placed 18" above the plastic.


 Prevent Adhesive failure- excess alkalinity(salts) can contribute to adhesive failure. Both the phenolphthalein and litmus paper tests measure the alkalinity of the surface of the concrete.     

PHENOLPHTHALEIN TEST : This moisture test uses a 3 percent phenolphthalein solution (fig 1) in water-free ethyl alcohol. Dime sized holes,1/4-inch deep, are drilled in various areas of the slab, particularly around walls. Then two drops of the solution are applied into each of the drilled areas. If there's no color change in the solution, there should not be enough moisture and the alkalinity is not high enough to affect the installation. But if the phenolphthalein turns pink or dark red within five minutes and the pH is 9.0 or higher, further testing must be done with a more precise method. This should NOT be the only method used for testing moisture.

Color of concrete surfaces : The "proper" color of concrete should be a light yellowish-grey (similar to limestone) not sugar white. In fact, a sugar-white surface usually means the concrete was improperly cured and can create a severe moisture problem later on (usually months later). This is due to the poor hydration of cement within the surface, creating a disproportionately high water to cement ratio...that appears white.

(fig. 1)

(fig. 2)

pH paper or litmus paper test:

 Determining if cement is alkali free is important for gluedown installations on concrete. Excess alkalinity(salts) can contribute to adhesive failure . Alkali can be visible as a white powder on the surface of the concrete. However, it is the excess salt contained within the concrete that can cause adhesive failure over time. This problem is magnified if moisture is present and passing through the concrete, as this condition will deposit the excess salt on the concrete surface. A simple pH test ( fig. 2) will determine the presence of alkali on a slab surface. Apply a few drops of distilled water to a small thoroughly clean and scraped concrete surface area and apply a strip of pH paper to the wetted area. The paper will change color within 5 minutes. Compare the color change to the chart standard supplied with the paper to indicate the pH of degree of alkalinity. A pH range from 5 to 10 is acceptable. Corrective measures must be taken with any concrete slab that measures a pH reading above10.

       


Testing new wood flooring and subfloors

Moisture Meters: probe and pinless

Probe or pin-type meters (fig. 1) are fast and easy to use. They come with different measurement indicators. The lower-cost units have L.E.D. display lights indicating different moisture levels; the better-quality units have analog or digital displays and provision for different species and wood temperatures.

The pinless meters (fig. 2) are also referred to as "non-destructive" because these don't leave small testing holes in the wood. Signal penetration for pinless meters is up to 1 inch for both hardwood and softwood. The meter can be moved across the surface to identify pockets of moisture in a wood block or plank. It is relatively unaffected by temperature. Rough surfaces have very little effect on the reading. Measurements can also be taken through coating, varnish or paint without damage to the surface.

One advantage of probe type meters is that those with insulated pins can measure moisture content at varying depths--you can tell whether the moisture content near the bottom of a board is higher than near the top.

Deciding which kind of moisture meter to buy is a matter of sorting through the features you think you will need, and how often you may use it, and then understanding the various features and benefits. It is important that the meter you choose offers the following: .

  • A clear analog or digital dial.
  • A moisture content range from at least 6 percent to 30 percent.
  • The necessary adjustment tables for various species;
    (some meters have a built in adjustment for this function)

(fig. 1)

(fig. 2)



Testing Wood Subfloors : Wood subfloors are actually easy to check for moisture content. Just test for moisture at several locations in the room and average the results (fig. 1) . In most regions of the country, a "dry" wood subfloor that is ready to work has a moisture content of 12 percent or less, or down to about 6% in states with low (RH) relative humidity. If excessively high readings are obtained, installation should not proceed until the origin of the moisture is identified and moisture problems are remedied. During the winter, an overly moist subfloor can be dried out by running the heat for a few weeks. Air conditioning during the summer will do the same thing.

Before installation, the moisture content of the subfloor should be within 4% percentage points of the new flooring (fig. 2) . If the moisture content between the new flooring and subflooring varies more than 4 percentage points or 2% for boards wider than 2 1/2" the flooring should not be installed.

(fig. 1)

(fig. 2)

Please direct inquiries to Lumber Liquidators Technical Department at 800-366-4204