Lumber Liquidators logo

Bostik DuraGrip




KEY FEATURES
-    Easy to trowel
-    Low odor & VOC
-    For all glue-down wood and bamboo flooring

DESCRIPTION
Bostik's DuraGrip TM is an easy-to-trowel urethane adhesive. It provides a tough, flexible, tenacious bond to a variety of surfaces. Bostik's DuraGrip TM elastomeric characteristics allow the adhesive to move with the wood as it expands and contracts over the life of the floor. This adhesive has low VOC's (as calculated per SCAQMD Rule 1168) and does NOT contain any water.

MOISTURE PROTECTION
For substrates that have an MVER of greater than recommended by the wood flooring manufacturer, use Bostik's MVP4 TM prior to the application of Bostik's DuraGrip TM for unlimited moisture vapor protection, or use Bostik's UltraGrip TM .

ANTI-FRACTURE PERFORMANCE
Bostiks DuraGripTM's elastomeric characteristics establish an anti-fracture membrane that can bridge cracks up to 1/8" (3mm) which can occur in the substrate prior to or after installation. This superior elasticity allows the adhesive to move with the wood as it expands and contracts with changes in humidity and temperature over the life of the floor.

ULTIMATE VERSATILITY
Bostik's DuraGrip TM may be used to adhere all engineered, solid, bamboo, cork, and parquet hardwood flooring. This adhesive can also be used to install plywood as described, as well as ceramic tile, marble, and stone inlays for light commercial and/ or residential applications.

Bostik's DuraGrip TM may be used over all properly prepared substrates common to hardwood flooring installations including: concrete, plywood, OSB, well bonded vinyl/VCT and ceramic tile, cement backer board, gypsum underlayments (dry, above-grade), cement patch/underlayments, radiant-heat flooring, and properly prepared terrazzo.

LEED CONTRIBUTION
Bostiks DuraGripTM 's low-VOC formulation (as calculated per SCAQMD Rule 1168) may contribute toward LEED credits under section EQ 4.1: Low-Emitting Materials - Adhesives & Sealants.

DIRECTIONS FOR USE
Read and understand data sheet completely before beginning installation. Follow industry standards and flooring manufacturer's recommendations for acclimation, design, layout, and application of wood flooring material. If jobsite conditions are outside of flooring manufacturer's recommendations, take necessary corrective actions.

SURFACE PREPARATION
All surfaces must be absorptive, clean, and free from loose materials, oil, grease, sealers, curing compounds, waxes, silicates, laitance, and all other surface contaminants that may inhibit proper bond. Completely remove cutback adhesive residue or other surface contaminants by diamond grinding to open the pores of the concrete. All surfaces to be treated must have a concrete surface profile (CSP) of 1-3 (similar to a broomed finish), as defined by ICRI (International Concrete Repair Institute, Guideline No. 03732). Maximum acceptable floor variation is 3/16" in 10 feet. Areas requiring patching or leveling must be done using a Portland cement-based material (e.g., Bostik's ULtraFinishT, Webcrete 95, Webcrete 98, or SL-150 TM SelfLeveling Underlayment). For cracks in concrete that are larger than 1/8", use a quality urethane sealant, such as Bostik's 915FS TM or 955-SL TM .

PLEASE NOTE: Concrete substrate should NOT be smooth and reflective; it must have a concrete surface profile of CSP 1-3 (similar to a broomed finish), as define by ICRI (International Concrete Repair Institute, Guideline No. 03732). It is advisable to test for adequate substrate absorption and texture in several areas throughout the jobsite by sprinkling droplets of water onto the slab. The drops of water should show signs of penetrating the substrate within one minute. This is evidenced by a water stain on the concrete without a "domed" droplet. If no signs of water penetration are shown within one minute and "domed" droplets remain (similar to drops on a car hood) the substrate must be scarified, shot blasted, or mechanically textured until it is absorptive.

INSTALLATION
The installation begins with a starter row secured to the subfloor; the starter row provides a stationary point to push against so flooring doesn't move during installation. Once the starter row is secured, apply adhesive/membrane to substrate using the appropriate trowel. See the chart on last page for proper trowel selection. Flooring may be installed using a "Wet-Lay" method of installation. For "Wet-Lay" installations, spread the adhesive and begin to install the flooring immediately. Periodically lift boards immediately after installation to ensure proper slab coverage and transfer to the back of the flooring. As you work, immediately clean any adhesive from prefinished flooring with Bostik's Ultimate TM Adhesive Remover or mineral spirits (be careful not to harm finish), then dry buff with a non-abrasive towel. After a few rows have been installed, and as you move across the room, tape the boards together using removable 3M #2080 Blue tape to prevent boards from sliding and to secure close-fitting joints. Rolling is recommended for all installations. Flooring that is not flat should be tacked, weighted, or rolled to ensure proper contact between the flooring and substrate.

PLYWOOD OVER CONCRETE: Score 4' x 4' or 2' x 8' sheets of 3/4" exterior-grade plywood on the backside every 8" to 10" by using a circular saw and cutting one-half the thickness of the plywood; "scoring or kerfing" takes the tension out of the plywood and helps to prevent possible warping or curling. Apply adhesive/membrane to substrate and then set plywood into the wet adhesive. Allow the adhesive to fully cure before nailing or using Bostik's DuraGrip TM adhesive to install flooring. If nailing to the plywood, nails must not protrude through to the adhesive.

CLEAN UP
As you work, immediately clean any adhesive from prefinished flooring with Bostik's Ultimate TM Adhesive Remover or mineral spirits (be careful not to harm finish), then dry buff with a nonabrasive towel. Immediately clean all tools and equipment with Bostik's Ultimate TM Adhesive Remover or mineral spirits before material cures.

TROWEL CLEAN-UP TIP: Before use, cover areas of the trowel that are not used to spread the adhesive with blue tape. After use, simply tear off tape before material cures, and clean the remainder of the trowel with adhesive remover.

STORAGE/SHELF LIFE
Store at temperatures between 50F and 100F (10C and 38C). Shelf life is one year from date of manufacturing in closed, original packaging.

Re-Seal Partially Used Container: With pail upright place a sheet of plastic (e.g., trash bag) over the top of the pail. Secure lid tightly over the plastic on top of pail. Carefully turn pail upside down. Plastic will help prevent the material from bonding the lid closed.

Re-Open Partially Used Container: Carefully turn pail right side up. Remove lid. Carefully cut and discard cured material and plastic from top of pail. Any uncured material may be used.

LIMITATIONS

  • Periodically check coverage and transfer of adhesive during installation.
  • Due to limitations with solid and bamboo wood flooring (e.g., lack of dimensional stability), "below-grade" installations are limited to engineered hardwood flooring.
  • For substrates with any history of moisture problems, or for concrete slabs exceeding the hardwood flooring manufacturer's recommendation, use a high performance moisture vapor reduction product such as Bostik's MVP4 TM prior to the application of Bostik's DuraGripT, or use Bostik's UltraGrip TM .
  • On- or below-grade substrates must have appropriate vapor barrier (6 mil poly or better) properly installed below slab.
  • Do not install solid wood flooring over VCT/vinyl.
  • Bamboo installations should follow solid hardwood flooring installation recommendations.
  • Slab temperature should be between 50F and 95F (10C and 35C) during installation.
  • Do not use on wet, dusty, contaminated, glassy smooth or friable substrates; do not use over substrates/slabs treated with sealers or curing compounds.
  • Completely remove all adhesive residue and other surface contaminants by diamond grinding, shot blasting, or scarifying.
  • Do not use over perimeter bonded flooring material.
  • Use over gypsum-based/underlayments is limited to dry, "above-grade" installations where the gypsum has dried hard (not dusty/powdery), with a minimum compressive strength > 2,000 psi for engineered hardwood installations, or minimum compressive strength > 2,500 psi for solid hardwood installations.
  • Please refer to flooring manufacturer's recommendations and NWFA's specifications for proper acclimation, verification of moisture content of flooring with a moisture meter, and expansion relief around perimeter throughout installation.
  • Do not use with vinyl-backed cork flooring or foamed-backed parquet.
  • Do not use in areas subject to hydrostatic head.
  • This adhesive does NOT reduce/affect issues originating from the sides, ends, or top of flooring (ie. puddles, water, leaks, hydrostatic-head, etc.).
  • This membrane does NOT eliminate moisture related or install related issues (i.e. improper acclimation of flooring, jobsite temperature/relative humidity, etc.).

PACKAGING
Available in 4 gallon pails (36 paiLs/paLLet).

CAUTION
COMBUSTIBLE. HARMFUL IF SWALLOWED OR INHALED. CONTAINS POTENTIAL SENSITIZER. MAY CAUSE ALLERGIC SKIN OR LUNG REACTION. MAY IRRITATE EYES, SKIN AND RESPIRATORY TRACT. Do not breathe fumes. Do not get in eyes, on skin or on clothing. Do not swallow. Use only in a well-ventilated area or wear mask. Keep away from flames or sparks. Wash thoroughly after handling. Store container in a cool (60-80F / 15-30C), dry area with lid tightly sealed. Do not reuse container.

LIMITED WARRANTY
Limited Warranty found at www.bostik-us.com or call 800.726.7845. TO THE MAXIMUM EXTENT ALLOWED BY LAW, BOSTIK DISCLAIMS ALL OTHER EXPRESS OR IMPLIED WARRANTIES, INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. UNLESS OTHERWISE STATED IN THE LIMITED WARRANTY, THE SOLE REMEDY FOR BREACH OF WARRANTY IS REPLACEMENT OF THE PRODUCT OR REFUND OF THE BUYER'S PURCHASE PRICE. BOSTIK DISCLAIMS ANY LIABILITY FOR DIRECT, INCIDENTAL, CONSEQUENTIAL, OR SPECIAL DAMAGES TO THE MAXIMUM EXTENT ALLOWED BY LAW. DISCLAIMERS OF IMPLIED WARRANTIES MAY NOT BE APPLICABLE TO CERTAIN CLASSES OF BUYERS AND SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATIONS MAY NOT APPLY TO YOU. It is the buyer's obligation to test the suitability of the product for an intended use prior to using it. The Limited Warranty extends only to the original purchaser and is not transferable or assignable. Any claim for a defective product must be filed within 30 days of discovery of a problem, and must be submitted with written proof of purchase.

OPEN TIME CHART

Temperature

Humidity

40%

60%

80%

60F (16C)

Tack

2 Hours

1.6 Hours

1.3 Hours

Open

3.5 Hours

3.5 Hours

3 Hours

70F (21C)

Tack

1.6 Hours

1.3 Hours

1 Hour

Open

3 Hours

3 Hours

2.5 Hours

80F (27C)

Tack

1.3 Hours

1 Hour

0.6 Hour

Open

3 Hours

2.5 Hours

2 Hours

Note: This chart is for reference only; actual jobsite times may vary.

CHEMICAL & PHYSICAL PROPERTIES

Use Environments

Residential

Yes

Offices/Light Commercial

Yes

Heavy Commercial

Yes

Hospital

No

Exterior

No

Wet Areas

No

Substrates

Concrete

Yes

Plywood

Yes

OSB

Yes

Well-Bonded Vinyl

Yes

Terrazzo

Yes

Ceramic Tile

Yes

Cement Backer Board

Yes

Gypsum Underlayments* 1

Yes

Cement Patch/Underlayment

Yes

Flooring Types

Solid Hardwood

Yes

Engineered Hardwood

Yes

Bamboo

Yes

Cork

Yes

Parquet

Yes

Plywood

Yes

Ceramic Tile, Marble, Stone Inlays* 2

Yes

Cured Physical Properties

Cure Time *3 Light foot traffic Normal foot traffic

8 to 10 hours 12 to 24 hours

Water Vapor Permeability* 4

< 0.9

Concrete Moisture Vapor Limits for subfloor moisture vapor protection:

Check wood flooring manufacturer's

Elongation

>180%

Service Temperature

-40F to 150F (-40C to 66C)

Application Properties

Ease of Troweling

Easy

Odor

Mild

Open/Working Time* 5

180 minutes

Color

White

Density (lbs/gallon)

13.8

Percentage of Water* 6

0%

Percentage of Adhesive Coverage Required:
Engineered
Solid

For Bond
>80%
>95%

Application Temperature

50F to 100F (10C to 38C)

Chemical Properties

Chemistry Type

1-Part Urethane

Adhesive Type

Moisture Cure

VOC Compliant (calculated per SCAQMD Rule 1168)

Yes (85 g/L)

Flash Point, closed cup

145F (61C)

* 1 Dry, above grade
* 2 Residential or light commercial only
* 3 Humidity affects cure to a greater degree than temperature; the higher the humidity, the faster the cure. Under normal conditions, light foot traffic is acceptable after 6 to 8 hours; normal traffic after 12-16 hours.
* 4 Per ASTM E-96 Standard Test Methods for Water Vapor Transmission of materials. Ratings are g/m2-24 hour-mmHG.

* 5 Please refer to the Open/Working Time Chart.
* 6 Per ASTM E203-01 Standard Test Method for water using Volumetric Karl Fischer Titration Method. Results rounded to the nearest tenth. Test Method has error range of +/_ 0.2%.


TROWEL SELECTION

In order to form a membrane that functions properly, the right trowel needs to be selected. Jobsite conditions, profile of the substrate, depth of back channeling in the flooring, and other factors affect the amount of adhesive that must be applied to achieve proper coverage and transfer. Always pull a board at the beginning of and during the installation process to confirm adequate coverage and transfer. Trowel size may need to be changed to achieve the required coverage and transfer. See trowel suggestions below.

ADHESIVE ONLY INSTALLATION METHOD

Suggested Notched Trowel (For use as an adhesive and moisture control membrane, refer to chart above.)

Engineered hardwood flooring <1/2" thick. Coverage: 50 sq.ft./gallon

<1/2" Parquet, or cork underlayment.

Coverage: 80 sq.ft./Gallon

Engineered hardwood flooring >1/2" thick, Solid wood or bamboo flooring <1/2" thick, and parquet <3/4" thick. Coverage: 40 sq.ft./gallon

Solid wood or bamboo flooring >1/2" thick, or plywood. Coverage: 35 sq.ft/gallon

Trowel size is suggested to maximize coverage of adhesive. Periodically check coverage of adhesive during installation: >80% coverage and transfer to the back of the flooring is required for all engineered wood flooring; >95% coverage and transfer is required for all solid wood flooring or bamboo flooring products.